artería insalubre Jajaja transformador 2500 kva administración ceja


microscop Contracție pasager transformer load calculation Confirmare

Eaton General purpose ventilated transformer, Fungus pr, AL windings, DOE 2016, NEMA 2, B+, 75 kVA, Made in USA, Fl/wall mt uprt, 3-ph, PV: 480V delta, SV: 208Y/120, NEMA ST-20, 2 at +2.5%, 4 at -2.5%, 75 kVA, Not required Product specifications Contact me about this product Dry-type distribution transformer flex center line card


SQUARE D 75 KVA transformer 75T76H 480V480/277 2 year warranty

Single-phase transformers are available as conventional (5-167kVA), completely self-protected (CSP 5-75kVA), or MagneX® interrupter-protected (5-167kVA) in a variety of ratings to meet or exceed the requirements of applicable ANSI® and NEMA® standards. Units designed per Rural Utilities Service (RUS) standards are also available.


75T3H Square D 75 KVA Transformer Breaker Outlet

Specifications: View a complete list of SQUARE D transformers Other 75 KVA Transformers 421-7232-000 75 KVA JEFFERSON TRANSFORMER - Stock No. 11-4371, 1 Phase, 208 Primary Voltage, 120/240 Secondary Voltage, 1+5%1-5% Taps, STANDARD Impedance Pct


Challenger 75 KVA, 3 Phase Transformer

GE 9T83B3874 Type QL Dry General Purpose Transformer, 480 VAC Primary, 208Y/120 VAC Secondary, 75 kVA, 60 Hz, 3 Phase. 75 kVA, 60 Hz, 3 Phase. Call it something else? Submit. SKU: G-E9T83B3874. Units are enclosed in a NEMA 2 drip proof metal enclosure with natural-draft ventilation. Core-and-coil assembly is mounted on rubber isolation pads.


Eaton V48M28T75EE 75 KVA 3 Pha Pri480V Sec208Y/120V Transformer

Schneider Electric Canada. EE75T65H - Transformer, dry type, 75kVA, 3 phase, 600V delta primary, 208Y/120V secondary, 20D, 150C rise.


Square D Transformer Supplier Worldwide Used Square D 75 kVA

Transformer, Dry Type, 75 kVA, 3-Phase, DOE 2016, 480 Delta Primary, 208Y/120 Volt AC, Secondary, 80C Rise, Copper Winding Also known as: 785901419471, EXN75T3HBCU Specifications Type: Dry Type, Transformer Volts AC Secondary: 120/208Y Volt Amps: 75kVA Volts AC Primary: 480 Delta.


ABB Distribution Transformer Supplier Worldwide Used ABB 75 kVA

Transformer, dry type, DOE 2016, 75kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 20M, 150C rise. Primary operational current 90.21 A 208.18 A 75 kVA Secondary voltage 208Y/120 V Coil Material Aluminium Basic IMP level (BIL) 10 kV. Net Weight 515.00 lb(US) (233.60 kg) 2 Mounting support Floor Floor, with 7400FMB


75 KVA Transformer Rentall Construction

Weight: 875 lb E-mail:[email protected]. Transformer Features: With a transformer rating of 75 kVA, the industrial transformer features a primary voltage of single-phase 7200/12470Y and a secondary voltage of single-phase 120/240V (L-L-N). This pole mount transformer


75 kVA Transformer 480V Delta Primary 120/240V Secondary NEMA 3R

Description: SQUARE D 75T3HNV : TRANSFORMER DRY 3PH 75KVA 480V-208Y/120V. Technical Description: 32 Inch W X 27 Inch D X 43.75 Inch H Size; 60 Hz Frequency Rating; 3 Phase (S); Indoor/Outdoor Application; Floor Mounting; IP55 Enclosure; 1025 lb Weight; Non Ventilated Construction; 75 kVA Power Rating; 480 V Delta Primary Voltage. UPC: 78590118112.


HAMMOND 0.75 kVA Transformer PH750QP Used 85046 eBay

Schneider Electric USA. EXN75T3HCU - Transformer, dry type, DOE 2016, 75kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 20M, 150C rise, Cu.


75 kva transformer r/wireporn

VA Rating - Transformer 75 kVA. Three Phase Transformer, Input 480VAC Delta. These Three Phase transformers offer consistent, smooth voltage transformation at 480VAC input. Transformers 15kVA and higher that meet DOE 2016 legislation will help lower operating costs, lower cost of ownership, increase profitability, and reduce overall greenhouse.


75 Kva Transformer for sale 61 ads for used 75 Kva Transformers

The total weight of a 75 kVA single-phase transformer can range from 400 to 700 kilograms while a three-phase 75 kVA transformer can weigh a little over 1 ton. Weight varies depending on the type of transformer, its cooling system, and other factors.


333 Kva Distribution Transformer, Commercial & Industrial, Construction

Transformer, Dry Type, 75 kVA, 480? Primary - 208Y/120 Secondary, 3-Phase, NEMA 3R, Aluminum Winding Also known as: 804766147098, 3F3Y075D16 Specifications Phase: 3 Volts AC Secondary: 120/208Y Volt Amps: 75kVA Volts AC Primary: 480 Delta Phase: 3 Volt Amps: 75kVA.


75 Kva Transformer Amps Chart My XXX Hot Girl

Schneider Electric USA. EE75T3H - Transformer, dry type, 75kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 20D, 150C rise.


75 Kva Transformer for sale 57 ads for used 75 Kva Transformers

General purpose DOE 2016 transformers, single-phase 15-100 kVA and three-phase 15-300 kVA, are manufactured in seismic certified (including OSHPD) NEMAT Type 2 enclosures with optional weathershields to make the enclosure NEMA 3R; wall mounting is available up to 112.5 kVA (1400 lb maximum weight).


Hammond Dry Type Transformer Wholesale Supplier Used 75 kVA 600V208Y

Description: ACME, Dry Type Transformer, Stock No. 11-1678, 3 Phase, KVA 75, Primary Voltage 600Y/347, Secondary Voltage 480Y/277, Taps, 115 ºC Temp Rating, 4.6 Impedance Pct., 262 Lbs. Weight, 19.00 Inches Height, 9.00 Inches Depth, Catalog Number T-3-52710-1. View a complete list of ACME transformers.

Scroll to Top